Files
libopencm3-examples/examples/stm32/f1/lisa-m-2/adc_injec_timtrig_irq_4ch
Karl Palsson eb54fbf285 adc: update to standardized calibrate api
Drop leftover code from before they were blocking, unify all to standard
api.
2016-10-01 16:13:45 +00:00
..

README

This is a simple example that sends the values read out from four ADC channels of the STM32 to the USART2.

This example uses a timer trigger to sample the injected adc channels and then uses an interrupt routine to retrieve the samples from the data registers.

The terminal settings for the receiving device/PC are 115200 8n1.